<ErrorNumber>44997</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: Focus sensor fails linearity test, check head position
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Should only occur in response to a "focus cal" command. Verify that the head is
properly installed and that head is in front of media. It is possible to do
just the error calibration part of focus cal using the "focus cal error"
command. If after proper head install this error persist then put back the
factory setting for head ferrcal since it may be possible to image regardless
of this error.
</text></DescriptionText>
<DescriptionText><text>
When doing a head install it is very important that the media thickness be
correct. Verify that media thk and media cthk are as expected and that right
media setting is enabled with the mode media command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The measured focus error as the final lens is moved is not a nice straight
line. Most likely head is not installed properly in front of media.
</Cause>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/focus_cal.xml</LinkAddress><LinkTitle>Command: focus cal</LinkTitle></Link>
<Link><LinkAddress>../commands/head_install_-install_mode-.xml</LinkAddress><LinkTitle>Command: head install &lt;install mode&gt;</LinkTitle></Link>
<Link><LinkAddress>../commands/mode_media_-number-.xml</LinkAddress><LinkTitle>Command: mode media &lt;number&gt;</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_ferrcal.xml</LinkAddress><LinkTitle>PRM: head ferrcal</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:43 2008 PST
</Updated>
<Links>
</Links>
</Error>